Maintaining your air conditioning units and systems are paramount for overall building efficiency.
We’ve outlined a basic maintenance checklist as well as the benefits of maintaining these systems below. If you need any help with air conditioning maintenance, simply get in touch with our expert team here at MFM Group.
Air Conditioning Maintenance Checklist
A checklist for a typical maintenance and servicing schedule for an air conditioning system should include the following:
- An inspection of the exterior condition of the equipment.
- An annual test for refrigerant leaks on each individual condenser/evaporator circuit in accordance with current legislation. This should include all integral soldered, flared and flanged joints. All seals and valves should be inspected for possible wear and tear. Any refrigerant leaks found should be reported.
- Condensers (air-cooled) should be inspected for free airflow and cleaning carried out either by reverse blowing or by brushing with a stiff brush.
- Evaporator coil should also be inspected for free airflow, cleaned and combed out if necessary.
- Compressors should be checked for smooth operation.
- Fan drive motors should be cleaned, checked, and the running currents also checked.
- All fan bearings should be inspected for the correct temperature and for silent and smooth running. The bearings should be lubricated as required.
- Drive belts should be checked for alignment, tension, wear and hardness and adjusted or replaced as required.
- The controls should be checked for correct operation setting, calibration and response.
- The safety controls should also be inspected for operation and settings.
- There should be an inspection of the solenoid valves, the motorised valve heads, and or the thermostatic expansion valves for operation, and they should be adjusted if necessary.
- Oil charges and levels should be inspected for any loss and rectified if necessary.
- Any water pumps, if fitted, should be checked for correct water temperature and any leakage.
- Refrigeration system pipe insulation should be inspected for any damage.
- Anti-vibration mountings, if fitted, should be checked for their effectiveness.
- Wiring should be checked for integrity.
- Where ‘electrode boiler’ type humidifiers have been installed, operation should be checked, water drained, and cylinders replaced if necessary.
- Air filters should be inspected, cleaned or replaced as necessary.
- Condensate and overflow drains should be tested and cleaned.
- The air on and air off temperatures from the indoor units should be checked and recorded.
- The inlet and outlet temperatures should be checked and recorded.
- A written service report should be provided and the customers F-Gas log books updated.
- Chemical treatment to remove bacteria, smells and odours is also recommended.
The Benefits of Air Conditioning Maintenance
Aside from the regulatory requirements, a system that is regularly serviced and maintained can save a company up to 40% in running costs, as well as saving money on costly future replacements. Often a small problem identified during a maintenance service can prevent them from becoming major and expensive problems later on.
Having your air conditioning equipment regularly serviced and maintained will ensure that you get longevity and optimal performance from your investment.
An efficient air conditioning unit is also good for the environment, reducing energy use and thereby reducing carbon out puts and the carbon footprint.
Regulations for Air Conditioning Systems
F-Gas Regulations
There are a host of reasons for having your air conditioning system regularly maintained and serviced. The first of these is that it is a legal requirement. The most important requirement relates to the 2014 F-Gas Regulation. This regulation contains a number of requirements affecting the use and maintenance of existing stationary air-conditioning equipment containing HFC refrigerants. The requirement depends on the type and size of equipment being used and relates to leak prevention, record keeping and the use of trained technicians.
It is prohibited to intentionally release F-Gases into the atmosphere and those operating stationary air-conditioning equipment must take measures to minimise leakage. When leaks are detected operators have to carry out repairs without delay.
For any business that operates an air conditioning system with a CO2 equivalent charge of 5 tonnes or more, it is a legal requirement to be F-Gas compliant. Since April 2018 fines for non-compliance have become very significant. A maximum fine of £200,000 could be enforced following the intentional release of F Gases into the environment. This is also deemed a criminal offence. Failure to comply with the regulations and procedures for minimising emissions, including leakages could result in a maximum penalty of £100,000. A fine of up to £50,000 could be incurred for failing to correctly label equipment or failing to keep proper records of F-Gases used in equipment. A maximum fine of £10,000 could also be incurred for minor breaches, including not reporting on F-Gas production within issued deadlines.
It is therefore vitally important that your system is regularly maintained and serviced by a professional air conditioning maintenance engineer. How often this needs to occur depends on the CO2 equivalent charge weight of your system.
A detailed service and maintenance record is a requirement for any air conditioning system which has an CO2 equivalent charge weight of 5 tonnes or more. Although the 2014 F-Gas Regulations are EU laws, they are likely to be replaced, post Brexit, by similar regulations and advice about these can be found here.
TM44 air conditioning inspections
TM44 is an energy efficiency assessment applied to any building’s air conditioning system with a rated output of 12kW or more.
It is a requirement that every commercial property with a qualifying air conditioning system has this assessment carried out every five years by a professional assessor. The assessment must then be registered on the NDEPC register.
R22 replacement
If you have an air-conditioning or refrigeration system that’s been in place for fifteen years or more, your system could be affected by the illegal refrigerant, R-22 HCFC. This gas was commonly used in air conditioning and refrigeration systems before 2003, but because of its harmful effect on the ozone layer, it has been banned since January 2015. As a result of this, the servicing, maintenance and recycling of R-22 HCFC in any air conditioning system is prohibited.
Learn More with MFM Group
Ultimately, by ensuring that your air conditioning system receives regular quality maintenance and servicing, you are guaranteeing that those working in the building are comfortable and therefore likely to be more productive. You are also ensuring that your system is cost effective and that you remain within the law.
For further advice on scheduling maintenance and servicing visits from expert engineers, contact us here at MFM Group today.